  • ESD小摆闸.webp

Anti Static Swing Gate Access Control

This product is an intelligent access control small swing gate specially designed for ESD (electrostatic discharge) testing areas. It is mainly used in places with strict requirements for electrostatic protection, such as dust-free workshops, laboratories, and electronic manufacturing plants. It uses card swiping, fingerprint or facial recognition to control personnel entry and exit, ensuring that only personnel who have passed ESD detection can enter the controlled area.


Keyword:

Anti-static gate - Swing gate

Product details


Product Overview   
This product is an intelligent access control small swing gate specially designed for ESD (electrostatic discharge) testing areas. It is mainly used in places with strict requirements for electrostatic protection, such as dust-free workshops, laboratories, and electronic manufacturing plants. It uses card swiping, fingerprint or facial recognition to control personnel entry and exit, ensuring that only personnel who have passed ESD detection can enter the controlled area.

 

Product Features   
ESD protection function: Equipped with advanced electrostatic detection module, it can accurately monitor whether personnel's electrostatic equipment meets the standards. Once an excessive situation is detected, the swing gate will immediately prohibit passage and trigger an alarm device.   
Multiple authentication methods: Provides rich identity authentication options, supporting IC card, fingerprint, facial recognition, password and other methods (flexible selection can be made according to actual functional requirements).   
Fast passage: The swing gate and swing arm respond extremely quickly, with a response time of ≤ 0.5 seconds. Adopting a two-way passage design, it effectively improves the efficiency of personnel passage.   
Anti tailgating design: Equipped with infrared sensing detection technology, it can keenly detect the passage of personnel, prevent multiple people from entering at the same time, and ensure access control security.   
Network management: Supports TCP/IP or RS485 communication, seamlessly integrates with access control management systems, and facilitates centralized management and data exchange.   
Durable material: The shell is made of 304 stainless steel or aluminum alloy material, which has excellent corrosion resistance and impact resistance, ensuring stable operation of the product in various environments.

 

Technical Specifications

ProjectParameter
Power supply voltageAC 220V±10% / DC 24V
Power≤50W
Operating temperature-20℃~60℃
Humidity range10%~90% RH (non condensing)
Passage width600-900mm (adjustable)
ESD detection range0.1M Ω~1000M Ω (threshold can be set)
Communication interfaceTCP/IP, RS485, Wiegand (optional)

Installation Instructions
Installation steps
Positioning: Accurately mark the installation position of the swing gate on the ground of the access control channel, ensuring that the installation surface is in a horizontal state.
Fixed base: Use expansion bolts to firmly fix the gate base to the ground.
Wiring: Connect the power supply, communication line, and ESD detection module strictly according to the wiring diagram.
Debugging: After powering on, carefully calibrate the infrared sensor and swing arm angle through the control panel.
Wiring diagram

 

Usage and Operation
Passage process
The user verifies their identity through a card reader, fingerprint scanner, or facial recognition terminal.
The system automatically detects the user's electrostatic resistance:
Qualified inspection: The swing arm automatically opens, the green light is on, and the user is allowed to pass.
Unqualified detection: The red light is on, the buzzer sounds an alarm, the swing arm is locked, and passage is prohibited.
After the user passes, the swing arm will automatically reset.
Management function
Parameter setting: ESD threshold, passage time, user permissions and other parameters can be flexibly set through management software.
Data export: Supports querying personnel travel time, personnel information, ESD detection results, and other records, and can export relevant data.

 

Maintenance and Troubleshooting

Common faults and solutions

Fault phenomenonPossible reasonsSolution
Swing brake does not operatePower not connected/motor malfunctionCheck the power cord/contact after-sales service
ESD detection failureSensor foulingClean the testing area
False alarmInfrared offsetRe calibrate the sensor

regular maintenance

Clean the surface of the swing gate and the infrared sensor every month.
Check the tightness of screws and the flexibility of swing arms every quarter.

 

Safety precautions

It is strictly prohibited to forcefully collide with the swing brake or hang heavy objects on the swing brake to avoid equipment damage.
During installation, it is necessary to ensure that the equipment is well grounded to avoid ESD interference that may affect the normal operation of the equipment.
Non professionals are not allowed to disassemble the circuit board to avoid safety accidents or equipment damage. 1. It is strictly prohibited to forcefully collide with the swing brake or hang heavy objects on the swing brake to avoid equipment damage.
During installation, it is necessary to ensure that the equipment is well grounded to avoid ESD interference that may affect the normal operation of the equipment.
Non professionals are not allowed to disassemble the circuit board to avoid safety accidents or equipment damage.

 

After-sales Service

This product comes with a 1-year warranty period (excluding non-human damage). During the warranty period, if there are any quality issues with the product, we will provide free repair or replacement services.

Online inquiry

Note: Please leave your E-mail address and our professionals will contact you as soon as possible!

DO YOU HAVE QUESTIONS?

Get in Touch With Us!

%{tishi_zhanwei}%

©Copyright 2025 Dongguan Jiehui Intelligent Technology Co., Ltd. All rights reserved

Business License